CC2001-T2 Timer Board, Dual Circuit.

APPLICATION
The CC2001-T2 TIMER BOARD, DUAL CIRCUIT is designed to upgrade an Industrial ConTel to a dual speech path and/or dual paging zone system to suit specific applications.

SPECIFICATIONS
Speech Paths: a) Intercom Line x 2
b) Paging Line x 2
Indicators: a) First (Default) Circuit
b) Second Circuit
Power Requirements: Supplied by the ConTel
Nominal 24VDC @ 20mA - 80mA
15VDC @ 30mA
Connections: Screw Terminals (With cable protectors)
Maximum cable size 1.5mm2
Size: 124mm (W) x 12mm (H) x 60mm (D)

CONNECTIONS
TS1-1 ConTel Line A
TS1-2 ConTel Line B
TS1-3 Line 1A
TS1-4 Line 1B
TS1-5 Line 2A
TS1-6 Line 2B


TS1-7 ConTel Page A
TS1-8 ConTel Page B
TS1-9 Page 1A
TS1-10 Page 1B
TS1-11 Page 2A
TS1-12 Page 2B


TS1-13 Spare A
TS1-14 Spare B
TS1-15 Spare A (nc)
TS1-16 Spare B (nc)
TS1-17 Spare A (no)
TS1-18 Spare B (no)
TS1-19 Not Used
TS1-20 Not Used


INSTALLATION
The CC2001-T2 Timer Board is intended to be contained within the ConTel unit to which it is connected.
Prior to installation check the 24v power supply rail. If the power supply rail is <20v consider the addition of a supplementary Power Supply Unit (CC2001/PSU) before proceeding. The CC2001-T2 Timer Board is fitted in the slots at the top of the ConTel unit after the connections detailed shown in Fig. 1 have been made.
Disconnect incoming Line 1 A & B and Page 1 A & B from TS1-1 to TS1-4 on the ConTel circuit board and connect these wires on the Timer Board as per Table1:-
Table 1
External wiring Timer Board
Line 1A TS1-3
Line 1B TS1-4
Page 1A TS1-9
Page 1B TS1-10

Make the following connections between the ConTel unit and the Timer Board as per the Table 2:-
Table 2
ConTel Timer Board
TS1-1 TS1-1
TS1-2 TS1-2
TS1-3 TS1-7
TS1-4 TS1-8

Connect incoming Line 2 A & B and Page 2 A & B on the Timer Board as per the Table 3:-
Table 3
External wiring Timer Board
Line 2A TS1-5
Line 2B TS1-6
Page 2A TS1-11
Page 2B TS1-12

The unit can be set-up to default to circuit 1 or 2 when using the handset to switch on the ConTel. (Default is the left hand yellow LED illuminated, Timer RESET) Set up PL3, PL4 and PL5 to alter relay switching as follows:-

Link removed Default Speech Path 1
Link in position A Default Speech Path 1
Link in position B Default Speech Path 2

Plug in the front panel connector (switches and LEDs) to PL1 on the Timer Board.
Plug in supply from CC2001-2 Interface board (flying-lead/connector) to PL2 on the Timer Board.

COMMISSIONING
1. Confirm default LED (left-hand yellow LED) switches on when the ConTel is activated by the handset switch. Confirm the green Unit Active indicator illuminates, and times out correctly (see CC2001/IND2 INDUSTRIAL CONTEL data sheet).
2. Confirm left-hand yellow LED indicator illuminates and that the green Unit Active indicator illuminates when the left-hand switch is momentarily depressed and released. Confirm the unit times out correctly.
3. Confirm right-hand yellow LED indicator illuminates and that the green Unit Active indicator illuminates when the right-hand switch is momentarily depressed and released. Confirm the unit times out correctly.
4. Confirm relay operation is as programmed by links PL3, PL4 and PL5

NB If any relay fails to operate and all connections and links are satisfactory, check the 24v power supply rail. If the power supply rail is <18v intermittent/mis-operation may result. Consider the addition of a supplementary Power Supply Unit, CC2001/PSU.

Figure 1

TYPICAL LAYOUT INSIDE THE CONTEL


Electromagnetic compatibility (EMC) directive. This equipment has been designed and manufactured to the highest standards. If connected and operated as set out in this manual, there should be no Electromagnetic Compatibility problems. If any aspect of operation gives rise to concern, then please contact the manufacture for advice.

This CONTEL STATION TIMER BOARD, DUAL CIRCUIT is supplied subject to our Terms & Conditions of Trade, a copy of which is available on request from Connect Communications, Tel 01366 728658. Because we are the manufacturer of the ConTel system, we are able to offer considerable flexibility to suit specific applications. We would be pleased to advise on any application not detailed above.

 

 